JSU-05A Counter

JSU-05A Counter
JSU-05A Counter
  • Categories:Electronic counter
  • MOQ:1
  • Brand:Trihero
  • FOB Port:Shanghai port, Ningbo port
  • Terms of Payment:Western Union, T/T, Paypal
  • Delivery Time:7 Working Days

JSU-05A Counter

Features:

1. Five large-screen LCD display, display large and clear.
2. Use ordinary AA battery, no external power supply, and convenient battery replacement
3. Press the PAUSE button to pause/count, press the PAUSE button again to resume counting
4. The input adopts ordinary contact signal, the sensor selection is simple and convenient, and the counting is accurate and reliable
5. Maximum counting speed: 20 times/sec
6. Reset: Panel/external
7. Anti-knock design, effectively prevent data loss
8. No mechanical wear, reliable work and long service life. 
9. Ultra-low power consumption.
10. Sleep memory function,when screen is turned off,counter will enter into memory sleep state,to resume previous data Please press PAUSE button.

Technical parameter:

Power supply: commonly used ordinary AA battery
Counting range: 0~99999
Maximum counting frequency: 20HZ
Minimum counting pulse width: 10mS
Maximum resistance of contact: ≤10KΩ
Minimum resistance of contact disconnection: ≥500KΩ

Clearing method: panel/external
Minimum pulse width for clearing: 0.1 seconds
Use environment temperature: -5~40℃
Dimensions: 64*38*38mm
Hole size: 61*36mm
Weight: a set of about 100 grams

Install the battery:

Unscrew the 2 shell fixing screws, gently separate the back cover (be careful not to break the signal line), insert a AA battery, close the back cover, and screw back the 2 shell fixing screws.

Usage:

Start counting: After counting terminals input contact signal, the counter starts counting.

Pause counting: press the COUNT/PAUSE button to pause counting; press the count/pause button (PAUSE) again to resume counting.
Panel reset: directly press the reset button (RESET).
External reset: reset directly when the external contact of the reset terminal is connected.

 Precautions:

1. The counting signal of the counter and the input switch or circuit of the clear signal should be as close as possible to the terminal of the counter, and the signal wire should be as short as possible.
2. Avoid the same tube or twisted wiring with others, such as strong current wires or power wires, to avoid unnecessary interference. If necessary, use shielded wires and connect the shielding layer to the counting terminal +.
3. Counting signal and clearing signal can only input contact signal, not other electrical signals.
4. The contact input should be reliable to avoid false counting and false zeroing caused by contact bounce.
5. When the LCD display is blurred, please replace with new batteries. When not in use for a long time, please remove the battery to prevent battery deterioration and leakage to damage the counter. After removing the battery, press the count/pause key (PAUSE) to make the screen display disappear to turn off the auxiliary battery inside the counter.